It is best to contact your Thermobile dealer or supplier first. They know your installation and can often help you straight away. If they cannot resolve the issue, please contact Thermobile UK on +44 (0)24 7635 7960 or sales@thermobile.co.uk.
Yes, all units are CE certified. The exception is IMA and IMAC models with a gas burner: the heater itself is CE certified, but the complete installation requires on-site approval.
We recommend having every heater serviced at least once a year by a qualified engineer. Gas-fired equipment must be serviced by a Gas Safe registered engineer and oil-fired equipment by a competent, preferably OFTEC-registered, technician. The exact requirements depend on the fuel, the application and the capacity of the unit. Our UK team can advise you.
Manuals can be found on our website under the relevant product.
That depends on the fault. Many parts are still available, but we cannot guarantee that every part is in stock for older models. Please contact our UK team with the model and serial number, and we will check availability and the options for repair.
We recommend performing major maintenance on the heater at least once a year. Additionally, depending on the type and application, it is advisable to carry out regular minor maintenance.
Thermobile guarantees that parts, or suitable alternatives, remain available for at least 10 years after a model has been discontinued. In practice, availability often extends well beyond that. For spare parts, please contact our UK team on +44 (0)24 7635 7960.
We have created a table as a guideline for the maximum hose lengths that can be connected to each unit.
No, for each heater type, we specify whether the connection is 230V or 400V.
Yes, all heaters must have a neutral (0) connection. If a neutral connection is not available, it is advisable to have a transformer installed on the heater to create a neutral connection.
Biodiesel comes in various types and compositions. The purest form is HVO, which can be used without any issues. Another type is FAME, which can be blended up to a maximum of 10% for optimal heater performance. For more information, please refer to our news article on environmentally friendly fuels.
Biodiesel is becoming increasingly available. However, not all biodiesel can be used without modifications. Please refer to our news article on environmentally friendly fuels for more information.
GTL (Gas-to-Liquids) is an alternative to regular diesel. It is produced from natural gas and has a molecular composition that results in lower emissions than conventional diesel. No modifications are needed to use GTL in existing equipment. GTL burns cleaner than diesel from crude oil, producing fewer nitrogen oxides (NOx) and sulphur oxides, and less visible black smoke (particulate matter).
This depends on the area and volume, minimum outdoor temperature, desired indoor temperature, insulation of the building, and application. You can calculate the required capacity for your space using our heat calculator.
This largely depends on the application, available fuel, and required capacity. You can calculate the required capacity using our calculation tool.
In a direct fired heater (such as the TA, TAS, GA, and AGA models), both the heat and combustion gases enter the room. In an indirect fired heater (such as the ITA, IMA, IMAC, BioEnergy, and ITLS models), heat and combustion gases are separated; only the heat enters the room, while the combustion gases are vented through a chimney.
This depends on the number of heaters and their capacity. It is best to ventilate based on measured CO2 levels to ensure there is never a risk of oxygen deficiency and carbon monoxide poisoning.
Yes, ventilation is generally required at all times, especially if there are many people or animals in the room. However, the amount of ventilation needed is much less than for direct fired heaters.
No, the capacity of a heater cannot and may not be increased. This can damage the heater and/or greatly shorten the lifespan of your heater. It also voids the warranty.
In principle, yes. However, electric heaters are only available in smaller capacities and their power consumption is high. Where more capacity is needed, a diesel or HVO heater is usually the more practical choice.
A GA heater cannot be converted from propane to natural gas. However, an AGA heater can be converted. Additionally, all heaters with gas-fired auxiliary burners can be converted from natural gas to propane and vice versa.
Yes, an AGA and all heaters with gas-fired auxiliary burners can be converted from natural gas to propane and vice versa.
All indirectly fired Thermobile heaters have an efficiency of over 90%. This already limits the emission of flue gases such as carbon dioxide and nitrogen oxides compared to heaters from many other suppliers with a much lower efficiency. Additionally, flue gas emissions can be further reduced by using recirculation, which also results in fuel savings. Furthermore, GTL can be used instead of regular diesel. GTL is a cleaner diesel that reduces flue gas emissions.
The maximum ambient temperature is 45°C. An exception to this is the TBD PC, specifically developed for pest control, which can operate in ambient temperatures up to 65°C.
If the chimney runs straight up, a length of up to 6 metres is not a problem. Only 45° bends are allowed; 90° bends are not permitted.
Only 45° bends are allowed, and no 90° bends. Limit the number of 45° bends to 2.
This depends largely on the number of heaters, the type of gas, the inlet pressure, and the total required capacity. It is best to consult your installer for this.
This also depends on the horizontal distance to be bridged. Up to approximately 1 meter in height, this should not be a problem.
For all heaters with an oil-fired auxiliary burner, the burner can be replaced with a gas-fired auxiliary burner.
This depends on the area and volume, insulation of the building and application. A rule of thumb is 40W per m3 for insulated buildings and 60W per m3 for tents, for example.
The temperature of the intake air is cooled back by about 12°C. It is therefore important to always recirculate the air from the room to be cooled. (In this case, the air is drawn in from the room and blown back into the room with a temperature approximately 12°C lower).