Home » Mobile Heating » IMA

IMA

The Thermobile IMA is a high-efficiency mobile indirect-fired air heater. Standard equipped with a maintenance-friendly Intercal front burner that can burn diesel, HVO and GTL. Suitable for heating larger spaces.

Need advice? Call or send a message

  • Diesel
  • Petroleum/Kerosene
  • HVO
  • GTL
  • Optional: Propane Gas
  • Optional: Natural Gas

IMA

Compare Performances
IMA-61 AX
IMA-61 AX

65 kW

More information
IMA-61 RAD
IMA-61 RAD

65 kW

More information
IMA-111 AX
IMA-111 AX

110 kW

More information
IMA-111 RDD
IMA-111 RDD

110 kW

More information
IMA-111 RHP
IMA-111 RHP

110 kW

More information
IMA-150 RAD
IMA-150 RAD

150 kW

More information
IMA-150 RHP
IMA-150 RHP

150 kW

More information
IMA-200 RAD
IMA-200 RAD
More information
IMA-200 RHP
IMA-200 RHP

200 kW

More information

Performance Chart

IMA-61 RAD IMA-111 RDD IMA-61 AX IMA-200 RAD IMA-150 RAD IMA-200 RHP IMA-111 AX IMA-111 RHP IMA-150 RHP
Max. Capacity (kW) 65 110 65 150 200 110 110 150
Air Displacement (m³/h) 4000 8000 4000 9000 13000 5800 10000 11000
Measured Amperage 230V (A) 6.5 15 3.3 15 4.4 7.5 9
Power Connection (V/ph/Hz) 230/1/50 230/1/50 230/1/50 230/1/50 400/3/50 230/1/50 400/3/50 40/3/50
Max. Fan Pressure (Pa) 250 300 130 300 500 130 500 500
Air Outlet Cone Ø (mm) 400 500 400 500 600 500 500 500
Chimney Connection Ø (mm) 180 200 180 200 200 200 200 200
Fuel Type
Max. Fuel Consumption (l/h) 6.5 10.9 6.5 14.8 19.4 10.9 10.9 14.8
Thermostat Connection Yes Yes Yes Yes Yes Yes Yes Yes
Dimensions LxWxH (cm) 199x71x128 223x78x134 162x71x128 246x84x151 271x91x152 179x78x134 223x78x134 246x84x151
Packaged Dimensions LxWxH (cm) 203x75x145 240x100x172 203x75x145 265x95x172 290x104x172 180x80x142 265x65x172
Weight (kg) 245 350 210 385 450 295 350 385
Packaged Weight (kg) 275 450 250 525 588 325 525
Measured Amperage (A)

Heat calculator

Calculate how much kW is needed for a specific room.
Characteristics
Automatic burner control with thermostat connection.
High-efficiency heat exchanger ( approx. 92% ).
Blow-out temperature with a delta ΔT of about 47°C.
Equipped with overheating protection and temperature limiter.
Fuel-efficient thanks to highly efficient heat exchanger and recirculation connection option.
Maintenance-friendly and easy to operate.
Easily movable.
Transport via wheels, forklift slots or lifting eyes.
Equipped with intercal industrial burner with flow control. Alternative burners available. (Riello oil or gas burner, for example).
Fleet Manager Essentials possible.
  • Applications
  • Documents
  • Heating of storage sheds, work areas, halls sorting areas, construction sites, greenhouses and polytunnels.
  • Drying of new construction and renovation projects.
  • Drying and preservation of agricultural products.
40019003__10__MANUAL__IMA__LR40022010__06 IMA 61 111 150 200 RAD40022020__03 IMA 61 111 150 AXIAAL

  • Heating of storage sheds, work areas, halls sorting areas, construction sites, greenhouses and polytunnels.
  • Drying of new construction and renovation projects.
  • Drying and preservation of agricultural products.

40019003__10__MANUAL__IMA__LR40022010__06 IMA 61 111 150 200 RAD40022020__03 IMA 61 111 150 AXIAAL

Frequently Asked Questions

The temperature of the intake air is cooled back by about 12°C. It is therefore important to always recirculate the air from the room to be cooled. (In this case, the air is drawn in from the room and blown back into the room with a temperature approximately 12°C lower).

This depends on the area and volume, insulation of the building and application. A rule of thumb is 40W per m3 for insulated buildings and 60W per m3 for tents, for example.

For all heaters with an oil-fired auxiliary burner, the burner can be replaced with a gas-fired auxiliary burner.

Read more

Get in touch!

Download our catalogue

In-house production
NL
European quality since 1958
Worldwide delivery
Customer-specific
Offers
  • Sectors
Sectors
  • Construction
  • Agriculture
  • Emergency heating
  • Military
  • Industry
  • Pest control
Additionals
  • Client projects
  • Careers
  • About us
  • Frequently Asked Questions

Route via Google Maps

Contact

Linkedin

  • Sectors

  • Construction
  • Agriculture
  • Emergency heating
  • Military
  • Industry
  • Pest control

  • Client projects
  • Careers
  • About us
  • Frequently Asked Questions

Route via Google Maps

Contact

Linkedin

  • Terms and Conditions
  • Privacybeleid
Part of
×
close close

Login

Forgot your password?

No account yet? Apply here