LX

ErP 2021 compliant suspended gas-fired unit heaters for industrial and commercial buildings, available for natural gas or LPG.

The Thermobile LX range provides suspended warm-air heating with low-NOx gas technology, high-low modulation and axial-fan freeblowing air distribution. The LX F models cover outputs from 15 to 140 kW.LX heaters are designed for warehouses, factories, logistics centres, hangars, horticultural buildings, showrooms and retail premises. Natural gas and LPG versions are available with injector change.

Need advice? Call +44 24 7635 7960 or send a message

  • Natural Gas (G20)
  • LPG (G31)

LX

Compare Performances
LX-15F
LX-15F

15.0 kW

More information
LX-20F
LX-20F

20.5 kW

More information
LX-25F
LX-25F

25.3 kW

More information
LX-30F
LX-30F

30.1 kW

More information
LX-35F
LX-35F

33.5 kW

More information
LX-40F
LX-40F

39.9 kW

More information
LX-50F
LX-50F

49.1 kW

More information
LX-60F
LX-60F

59.1 kW

More information
LX-70F
LX-70F

69.8 kW

More information
LX-90F
LX-90F

88.4 kW

More information
LX-120F
LX-120F

119.2 kW

More information
LX-140F
LX-140F

138.3 kW

More information

Performance Chart

LX-15F LX-30F LX-25F LX-35F LX-40F LX-140F LX-70F LX-20F LX-60F LX-90F LX-120F LX-50F
Max. Capacity (kW) 15.0 30.1 25.3 33.5 39.9 138.3 69.8 20.5 59.1 88.4 119.2 49.1
Minimum heat output low fire (kW) 8.5 16.1 11.7 16.1 19.8 72.7 34.0 10.5 29.9 41.2 67.7 23.8
Gas input high fire nett CV (kW) 16.2 32.1 27.4 35.8 43.1 147.5 75.3 22.2 64.2 94.9 127.0 53.6
Gas input low fire nett CV (kW) 8.9 16.5 12.2 16.8 20.5 75.0 35.1 11.0 31.9 43.6 70.1 25.1
Seasonal NOx (mg/kWh) 63.8 59.0 51.7 66.8 44.4 61.2 53.9 60.0 60.2 38.7 66.8 48.3
Seasonal space heating energy efficiency (%) 78.2 80.7 79.5 80.5 80.1 80.0 80.5 78.9 79.0 79.8 79.6 79.2
Natural gas consumption (m³/h) 1.71 3.39 2.90 3.79 4.56 15.60 7.96 2.35 6.79 10.03 13.43 5.67
LPG consumption (m³/h) 0.66 1.31 1.12 1.46 1.76 6.03 3.08 0.91 2.62 3.88 5.19 2.19
Nominal natural gas inlet pressure (mbar) 20 20 20 20 20 20 20 20 20 20 20 20
Nominal LPG inlet pressure (mbar) 37 37 37 37 37 37 37 37 37 37 37 37
Airflow volume (m³/s) 0.47 0.97 0.78 1.11 1.18 3.75 1.94 0.56 1.83 2.81 3.56 1.51
Airflow volume (m³/h) 1692 3492 2808 3996 4248 13500 6984 2016 6588 10116 12816 5436
Air throw (m) 10 23 20 28 30 45 42 14 38 44 45 35
Run current LX F (A) 0.9 1.2 1.0 1.7 1.3 4.7 2.4 1.0 2.5 3.2 4.6 1.8
Start current LX F (A) 1.9 2.4 2.0 4.0 2.7 8.0 4.0 2.0 5.0 6.0 8.0 4.0
Standard electrical supply (V/ph/Hz) 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50
Heat exchanger Four-pass aluminised steel; 409/316 stainless upgrades available Four-pass aluminised steel; 409/316 stainless upgrades available Four-pass aluminised steel; 409/316 stainless upgrades available Four-pass aluminised steel; 409/316 stainless upgrades available Four-pass aluminised steel; 409/316 stainless upgrades available Four-pass aluminised steel; 409/316 stainless upgrades available Four-pass aluminised steel; 409/316 stainless upgrades available Four-pass aluminised steel; 409/316 stainless upgrades available Four-pass aluminised steel; 409/316 stainless upgrades available Four-pass aluminised steel; 409/316 stainless upgrades available Four-pass aluminised steel; 409/316 stainless upgrades available Four-pass aluminised steel; 409/316 stainless upgrades available
Gas valve Modulating Modulating Modulating Modulating Modulating Modulating Modulating Modulating Modulating Modulating Modulating Modulating
Flue diameter (mm) 80 100 80 100 100 130 130 80 130 130 130 100
Maximum flue length - flue only (m) 12 12 12 12 12 12 12 12 12 12 12 12
Maximum flue length - room sealed (m) 6 6 6 6 6 6 6 6 6 6 6 6
Minimum mounting height (m) 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5
Overall height (mm) 450 670 570 532 720 1140 912 500 760 810 975 684
Overall width (mm) 997 997 997 1325 997 1950 1325 997 1325 1950 1950 1325
Overall depth (mm) 859 834 819 918 834 915 915 869 915 938 915 938
Noise level at 5 m (dB(A)) 48 50 47 50 58 64 60 47 60 63 64 59
Net weight (kg) 59.5 81 76.5 84.0 103 286 149 73.0 135 202 238 122
Casing colour RAL 7015 RAL 7015 RAL 7015 RAL 7015 RAL 7015 RAL 7015 RAL 7015 RAL 7015 RAL 7015 RAL 7015 RAL 7015 RAL 7015

Heat calculator

Calculate how much kW is needed for a specific room.
Characteristics
Suspended warm-air unit heater with axial fan crossflow configuration
ErP 2021 compliant low-NOx gas heating
Four-pass tubular heat exchanger
G20 natural gas or G31 LPG with injector change
Modulating gas valve assembly supplied as standard
MC200 Optimised Start Control
Six top suspension points
RAL 7015 epoxy powder-coated casing
  • Applications
  • Warehouses and industrial storage buildings
  • Factories and production halls
  • Garage workshops
  • Distribution and logistics centres
  • Aircraft hangars
  • Garden centres and horticultural premises
  • Showrooms and retail outlets

  • Warehouses and industrial storage buildings
  • Factories and production halls
  • Garage workshops
  • Distribution and logistics centres
  • Aircraft hangars
  • Garden centres and horticultural premises
  • Showrooms and retail outlets

Frequently Asked Questions

The temperature of the intake air is cooled back by about 12°C. It is therefore important to always recirculate the air from the room to be cooled. (In this case, the air is drawn in from the room and blown back into the room with a temperature approximately 12°C lower).

This depends on the area and volume, insulation of the building and application. A rule of thumb is 40W per m3 for insulated buildings and 60W per m3 for tents, for example.

For all heaters with an oil-fired auxiliary burner, the burner can be replaced with a gas-fired auxiliary burner.

Read more

Get in touch!

Send an Email +44 24 7635 7960

Download our catalogue

In-house production
NL
European quality since 1958
Worldwide delivery
Customer-specific
Offers
  • Sectors
Sectors
  • Construction
  • Agriculture
  • Emergency heating
  • Military
  • Industry
  • Pest control
Additionals
  • Client projects
  • Careers
  • About us
  • Frequently Asked Questions
Thermobile UK Limited

11 & 12 Buckingham Close, Bermuda Industrial Estate

Nuneaton, Warwickshire CV10 7JT

United Kingdom

Route via Google Maps

+44 24 7635 7960

Contact

Linkedin

  • Sectors

  • Construction
  • Agriculture
  • Emergency heating
  • Military
  • Industry
  • Pest control

  • Client projects
  • Careers
  • About us
  • Frequently Asked Questions

11 & 12 Buckingham Close, Bermuda Industrial Estate

Nuneaton, Warwickshire CV10 7JT

United Kingdom

Route via Google Maps

+44 24 7635 7960

Contact

Linkedin

  • Terms and Conditions
  • Privacy policy
Part of
×
close close

Login

Forgot your password?

No account yet? Apply here