Home » Mobile Heating » OUH

OUH

Suspended indirect oil-fired heaters for warehouses, factories and commercial premises. OUH-30, OUH-45 and OUH-60 provide high/low heating with a stainless steel heat exchanger.

The Thermobile OUH range provides indirect oil-fired warm-air heating where floor space is valuable. The selected OUH-30, OUH-45 and OUH-60 models cover maximum outputs of 30, 45 and 60 kW.The range is available with an axial fan for freeblowing applications or a centrifugal fan for ducted systems. A 304 grade stainless steel heat exchanger and Riello Gulliver high/low burner are standard features. Specify the fan configuration and oil grade when ordering.

Need advice? Call +44 24 7635 7960 or send a message

  • 35-second heating oil
  • 28-second oil / kerosene option

OUH

Compare Performances
OUH-30
OUH-30

30 kW

More information
OUH-45
OUH-45

45 kW

More information
OUH-60
OUH-60

60 kW

More information

Performance Chart

OUH-60 OUH-30 OUH-45
Max. Capacity (kW) 60 30 45
Minimum heat output (kW) 45 24 34
Fuel options 35-second heating oil / 28-second oil; burner specification to be confirmed 35-second heating oil / 28-second oil; burner specification to be confirmed 35-second heating oil / 28-second oil; burner specification to be confirmed
Oil consumption (l/h) 6.70 3.18 5.32
Oil connection (BSP/Rc) 1/4 inch 1/4 inch 1/4 inch
Heat exchanger 304 stainless steel 304 stainless steel 304 stainless steel
Burner Riello Gulliver high/low Riello Gulliver high/low Riello Gulliver high/low
Standard power supply (V/ph/Hz) 230/1/50 230/1/50 230/1/50
Optional power supply (V/ph/Hz) 415/3/50 415/3/50 415/3/50
Airflow - OUH F (m³/s) 1.94 0.82 1.19
Airflow - OUH C (m³/s) 1.88 0.82 1.19
Airflow - OUH F (m³/h) 6984 2952 4284
Airflow - OUH C (m³/h) 6768 2952 4284
Air throw - OUH F (m) 34 16 25
Fan static pressure - OUH C (Pa) 384 305 275
Running current - OUH F (A) 1.7 0.46 0.48
Running current - OUH C (A) 8.0 4.33 5.54
Minimum mounting height - OUH F (m) 3 2.5 3
Maximum mounting height - OUH F (m) 5 3 5
Overall height (mm) 1049 1043 1049
Overall width (mm) 780 780 780
Depth - OUH F (mm) 1150 1106 1115
Depth - OUH C (mm) 1469 1470 1469
Flue diameter (mm) 125 125 125
Optional combustion air spigot (mm) 150 150 150
Maximum combustion duct length (m) 21 100 81
Sound level at 5 m - OUH F (dB(A)) 53 54 52
Net weight - OUH F (kg) 126 126 126
Net weight - OUH C (kg) 142 142 142
Installation clearance - top (mm) 1000 1000 1000
Installation clearance - side (mm) 500 500 500
Installation clearance - rear (mm) 400 400 400

Heat calculator

Calculate how much kW is needed for a specific room.
Characteristics
Suspended indirect oil-fired warm-air heating
304 grade stainless steel heat exchanger
Pre-fitted and tested Riello Gulliver high/low oil burner
Freeblowing axial fan and centrifugal ducted configurations available
Adjustable horizontal louvres on OUH F models
Standard 230 V single-phase electrical supply
  • Applications
  • Warehouses and industrial storage buildings
  • Factories and production halls
  • Garage workshops, subject to site assessment
  • Distribution and logistics centres
  • Horticultural premises and garden centres
  • Showrooms and retail premises

  • Warehouses and industrial storage buildings
  • Factories and production halls
  • Garage workshops, subject to site assessment
  • Distribution and logistics centres
  • Horticultural premises and garden centres
  • Showrooms and retail premises

Frequently Asked Questions

The temperature of the intake air is cooled back by about 12°C. It is therefore important to always recirculate the air from the room to be cooled. (In this case, the air is drawn in from the room and blown back into the room with a temperature approximately 12°C lower).

This depends on the area and volume, insulation of the building and application. A rule of thumb is 40W per m3 for insulated buildings and 60W per m3 for tents, for example.

For all heaters with an oil-fired auxiliary burner, the burner can be replaced with a gas-fired auxiliary burner.

Read more

Get in touch!

Send an Email +44 24 7635 7960

Download our catalogue

In-house production
NL
European quality since 1958
Worldwide delivery
Customer-specific
Offers
  • Sectors
Sectors
  • Construction
  • Agriculture
  • Emergency heating
  • Military
  • Industry
  • Pest control
Additionals
  • Client projects
  • Careers
  • About us
  • Frequently Asked Questions
Thermobile UK Limited

11 & 12 Buckingham Close, Bermuda Industrial Estate

Nuneaton, Warwickshire CV10 7JT

United Kingdom

Route via Google Maps

+44 24 7635 7960

Contact

Linkedin

  • Sectors

  • Construction
  • Agriculture
  • Emergency heating
  • Military
  • Industry
  • Pest control

  • Client projects
  • Careers
  • About us
  • Frequently Asked Questions

11 & 12 Buckingham Close, Bermuda Industrial Estate

Nuneaton, Warwickshire CV10 7JT

United Kingdom

Route via Google Maps

+44 24 7635 7960

Contact

Linkedin

  • Terms and Conditions
  • Privacy policy
Part of
×
close close

Login

Forgot your password?

No account yet? Apply here