PSO

The Thermobile PSO range consists of indirect oil-fired cabinet heaters for warehouses, factories, garage workshops, distribution and logistics centres, aircraft hangars, garden centres and other large industrial or commercial spaces.PSO heaters are available in outputs from 30 to 300 kW. Standard upright freeblowing models distribute warm air directly through adjustable discharge heads. High/low output, factory-fitted safety controls and a two-pass heat exchanger provide controlled and efficient heating in a robust cabinet design.

Need advice? Call or send a message

  • Diesel|Petroleum/Kerosene

PSO

Compare Performances
PSO-30
PSO-30
More information
PSO-60
PSO-60
More information
PSO-90
PSO-90
More information
PSO-120
PSO-120
More information
PSO-150
PSO-150
More information
PSO-175
PSO-175
More information
PSO-200
PSO-200
More information
PSO-250
PSO-250
More information
PSO-300
PSO-300
More information

Performance Chart

PSO-200 PSO-175 PSO-150 PSO-250 PSO-60 PSO-120 PSO-90 PSO-300 PSO-30
Configuration Upright freeblowing (UF) Upright freeblowing (UF) Upright freeblowing (UF) Upright freeblowing (UF) Upright freeblowing (UF) Upright freeblowing (UF) Upright freeblowing (UF) Upright freeblowing (UF) Upright freeblowing (UF)
Fuel Oil Oil Oil Oil Oil Oil Oil Oil Oil
Maximum heat output (kW) 200 175 150 250 60 120 90 300 30
Minimum heat output (kW) 140 123 105 175 42 84 63 210 21
Thermal efficiency - net CV (%) 91.5 91.5 91.5 91.5 91.5 91.5 91.5 91.5 91.5
Airflow (m³/h) 13824 12096 10368 17280 4140 8280 6228 20736 2088
Air throw (m) 28 28 28 40 18 23 23 47 14
Number of discharge heads 4 4 4 4 3 4 3 4 2
Discharge head diameter (mm) 406 356 305 457 254 305 305 457 203
Standard fan static pressure (Pa) 100 190 175 60 185 140 100 150 188
Power supply (V/ph/Hz) 400/3/50 400/3/50 400/3/50 400/3/50 230/1/50 400/3/50 230/1/50 400/3/50 230/1/50
Starting current - standard fan (A) 38.0 20.8 32.5 58.0 8.1 13.1 12.0 32.0 6.5
Running current - standard fan (A) 6.5 6.9 5.1 9.0 4.4 4.8 6.8 14.4 4.2
Oil consumption (l/h) 21.17 18.89 15.90 26.73 6.38 12.95 9.70 31.36 3.16
Oil connection (BSP/Rc) 3/8 inch 3/8 inch 3/8 inch 3/8 inch 3/8 inch 3/8 inch 3/8 inch 3/8 inch 3/8 inch
Flue diameter (mm) 175 175 175 200 150 150 150 200 125
Sound level at 5 m (dB(A)) 74 73 62 75 61 70 63 77 56
Net weight - standard upright (kg) 530 530 386 556 231 341 241 556 168
Height including discharge heads (mm) 3174 3054 2821 3307 2494 2821 2585 3307 2024
Width (mm) 904 904 904 1104 744 904 744 1104 669
Depth excluding burner (mm) 1399 1399 1200 1599 927 1200 927 1599 732

Heat calculator

Calculate how much kW is needed for a specific room.
Characteristics
Available in outputs from 30 to 300 kW.
Indirect oil-fired heating with a two-pass tubular heat exchanger.
Upright freeblowing models with adjustable discharge heads.
High/low heat output is standard for most space-heating applications.
Factory-fitted safety controls include high-limit protection and flame monitoring.
Robust cabinet construction for industrial and commercial use.

Frequently Asked Questions

The temperature of the intake air is cooled back by about 12°C. It is therefore important to always recirculate the air from the room to be cooled. (In this case, the air is drawn in from the room and blown back into the room with a temperature approximately 12°C lower).

This depends on the area and volume, insulation of the building and application. A rule of thumb is 40W per m3 for insulated buildings and 60W per m3 for tents, for example.

For all heaters with an oil-fired auxiliary burner, the burner can be replaced with a gas-fired auxiliary burner.

Read more

Get in touch!

Download our catalogue

In-house production
NL
European quality since 1958
Worldwide delivery
Customer-specific
Offers
  • Sectors
Sectors
  • Construction
  • Agriculture
  • Emergency heating
  • Military
  • Industry
  • Pest control
Additionals
  • Client projects
  • Careers
  • About us
  • Frequently Asked Questions

Route via Google Maps

Contact

Linkedin

  • Sectors

  • Construction
  • Agriculture
  • Emergency heating
  • Military
  • Industry
  • Pest control

  • Client projects
  • Careers
  • About us
  • Frequently Asked Questions

Route via Google Maps

Contact

Linkedin

  • Terms and Conditions
  • Privacybeleid
Part of
×
close close

Login

Forgot your password?

No account yet? Apply here