OUH
Suspended indirect oil-fired heaters for warehouses, factories and commercial premises. OUH-30, OUH-45 and OUH-60 provide high/low heating with a stainless steel heat exchanger.
The Thermobile OUH range provides indirect oil-fired warm-air heating where floor space is valuable. The selected OUH-30, OUH-45 and OUH-60 models cover maximum outputs of 30, 45 and 60 kW.The range is available with an axial fan for freeblowing applications or a centrifugal fan for ducted systems. A 304 grade stainless steel heat exchanger and Riello Gulliver high/low burner are standard features. Specify the fan configuration and oil grade when ordering.
Need advice? Call +44 24 7635 7960 or send a message
Specifications
-
45
-
34
-
5.32
-
1/4 inch
-
304 stainless steel
-
Riello Gulliver high/low
-
230/1/50
-
415/3/50
-
1.19
-
1.19
-
4284
-
4284
-
25
-
275
-
0.48
-
5.54
-
3
-
5
-
1049
-
780
-
1115
-
1469
-
125
-
150
-
81
-
52
-
126
-
142
-
1000
-
500
-
400
Characteristics
Suspended indirect oil-fired warm-air heating
304 grade stainless steel heat exchanger
Pre-fitted and tested Riello Gulliver high/low oil burner
Freeblowing axial fan and centrifugal ducted configurations available
Adjustable horizontal louvres on OUH F models
Standard 230 V single-phase electrical supply
- Warehouses and industrial storage buildings
- Factories and production halls
- Garage workshops, subject to site assessment
- Distribution and logistics centres
- Horticultural premises and garden centres
- Showrooms and retail premises
OUH
Compare Performances
Performance Chart
| OUH-45 | OUH-60 | OUH-30 | |
|---|---|---|---|
| Max. Capacity (kW) | 45 | 60 | 30 |
| Minimum heat output (kW) | 34 | 45 | 24 |
| Fuel options | 35-second heating oil / 28-second oil; burner specification to be confirmed | 35-second heating oil / 28-second oil; burner specification to be confirmed | 35-second heating oil / 28-second oil; burner specification to be confirmed |
| Oil consumption (l/h) | 5.32 | 6.70 | 3.18 |
| Oil connection (BSP/Rc) | 1/4 inch | 1/4 inch | 1/4 inch |
| Heat exchanger | 304 stainless steel | 304 stainless steel | 304 stainless steel |
| Burner | Riello Gulliver high/low | Riello Gulliver high/low | Riello Gulliver high/low |
| Standard power supply (V/ph/Hz) | 230/1/50 | 230/1/50 | 230/1/50 |
| Optional power supply (V/ph/Hz) | 415/3/50 | 415/3/50 | 415/3/50 |
| Airflow - OUH F (m³/s) | 1.19 | 1.94 | 0.82 |
| Airflow - OUH C (m³/s) | 1.19 | 1.88 | 0.82 |
| Airflow - OUH F (m³/h) | 4284 | 6984 | 2952 |
| Airflow - OUH C (m³/h) | 4284 | 6768 | 2952 |
| Air throw - OUH F (m) | 25 | 34 | 16 |
| Fan static pressure - OUH C (Pa) | 275 | 384 | 305 |
| Running current - OUH F (A) | 0.48 | 1.7 | 0.46 |
| Running current - OUH C (A) | 5.54 | 8.0 | 4.33 |
| Minimum mounting height - OUH F (m) | 3 | 3 | 2.5 |
| Maximum mounting height - OUH F (m) | 5 | 5 | 3 |
| Overall height (mm) | 1049 | 1049 | 1043 |
| Overall width (mm) | 780 | 780 | 780 |
| Depth - OUH F (mm) | 1115 | 1150 | 1106 |
| Depth - OUH C (mm) | 1469 | 1469 | 1470 |
| Flue diameter (mm) | 125 | 125 | 125 |
| Optional combustion air spigot (mm) | 150 | 150 | 150 |
| Maximum combustion duct length (m) | 81 | 21 | 100 |
| Sound level at 5 m - OUH F (dB(A)) | 52 | 53 | 54 |
| Net weight - OUH F (kg) | 126 | 126 | 126 |
| Net weight - OUH C (kg) | 142 | 142 | 142 |
| Installation clearance - top (mm) | 1000 | 1000 | 1000 |
| Installation clearance - side (mm) | 500 | 500 | 500 |
| Installation clearance - rear (mm) | 400 | 400 | 400 |