Cart Items 0
  • Frequently Asked Questions
  • About us
  • Careers
  • Service & Support
  • Contact
close
  • close
    • EN
      • NL
      • DE
      • FR
  • Login
  • Cart Items 0
  • Login Account
  • Location NL
  • close
Menu
  • Mobile Heating
  • Mobile Cooling
  • Mobile Dehumidification
  • Accessories
  • Sectors
    Sectors
    • Agriculture
    • Construction
    • Emergency heating
    • Events
    • Industry
    • Military
    • Pest control
    • Rental
  • Frequently Asked Questions
  • About us
  • Careers
  • Service & Support
  • Contact
  • Mobile Heating
  • Mobile Cooling
  • Mobile Dehumidification
  • Accessories
  • Sectors
Home » Mobile Heating » IMA

IMA

The Thermobile IMA is a high-efficiency mobile indirect-fired air heater. Standard equipped with a maintenance-friendly Intercal front burner that can burn diesel, HVO and GTL. Suitable for heating larger spaces.

Need advice? Call +31 (0)7 65 87 34 50
 or send a message

  • Diesel
  • Petroleum/Kerosene
  • HVO
  • GTL
  • Optional: Propane Gas
  • Optional: Natural Gas

IMA

Compare Performances
IMA-61 AX
IMA-61 AX

65 kW

More information
IMA-61 RAD
IMA-61 RAD

65 kW

More information
IMA-111 AX
IMA-111 AX

110 kW

More information
IMA-111 RDD
IMA-111 RDD

110 kW

More information
IMA-111 RHP
IMA-111 RHP

110 kW

More information
IMA-150 RAD
IMA-150 RAD

150 kW

More information
IMA-150 RHP
IMA-150 RHP

150 kW

More information
IMA-200 RAD
IMA-200 RAD
More information
IMA-200 RHP
IMA-200 RHP

200 kW

More information

Performance Chart

IMA-61 AX IMA-150 RAD IMA-200 RHP IMA-150 RHP IMA-111 RHP IMA-111 AX IMA-200 RAD IMA-61 RAD IMA-111 RDD
Max. Capacity (kW) 65 150 200 150 110 110 65 110
Air Displacement (m³/h) 4000 9000 13000 11000 10000 5800 4000 8000
Measured Amperage 230V (A) 3.3 15 9 7.5 4.4 6.5 15
Power Connection (V/ph/Hz) 230/1/50 230/1/50 400/3/50 40/3/50 400/3/50 230/1/50 230/1/50 230/1/50
Max. Fan Pressure (Pa) 130 300 500 500 500 130 250 300
Air Outlet Cone Ø (mm) 400 500 600 500 500 500 400 500
Chimney Connection Ø (mm) 180 200 200 200 200 200 180 200
Max. Fuel Consumption (l/h) 6.5 14.8 19.4 14.8 10.9 10.9 6.5 10.9
Thermostat Connection Yes Yes Yes Yes Yes Yes Yes Yes
Dimensions LxWxH (cm) 162x71x128 246x84x151 271x91x152 246x84x151 223x78x134 179x78x134 199x71x128 223x78x134
Packaged Dimensions LxWxH (cm) 203x75x145 265x95x172 290x104x172 265x65x172 180x80x142 203x75x145 240x100x172
Weight (kg) 210 385 450 385 350 295 245 350
Packaged Weight (kg) 250 525 588 525 325 275 450
Measured Amperage (A) 10
Fuel Type Diesel, GTL, HVO, Natural gas, Petroleum/kerosene, Propane Diesel, GTL, HVO, Natural gas, Petroleum/kerosene, Propane Diesel, GTL, HVO, Natural gas, Petroleum/kerosene, Propane Diesel, GTL, HVO, Natural gas, Petroleum/kerosene, Propane Diesel, GTL, HVO, Natural gas, Petroleum/kerosene, Propane

Heat calculator

Calculate how much kW is needed for a specific room.
Characteristics
Automatic burner control with thermostat connection.
High-efficiency heat exchanger ( approx. 92% ).
Blow-out temperature with a delta ΔT of about 47°C.
Equipped with overheating protection and temperature limiter.
Fuel-efficient thanks to highly efficient heat exchanger and recirculation connection option.
Maintenance-friendly and easy to operate.
Easily movable.
Transport via wheels, forklift slots or lifting eyes.
Equipped with intercal industrial burner with flow control. Alternative burners available. (Riello oil or gas burner, for example).
Fleet Manager Essentials possible.
  • Applications
  • Documents
  • Heating of storage sheds, work areas, halls sorting areas, construction sites, greenhouses and polytunnels.
  • Drying of new construction and renovation projects.
  • Drying and preservation of agricultural products.
40019003__10__MANUAL__IMA__LR40022010__06 IMA 61 111 150 200 RAD40022020__03 IMA 61 111 150 AXIAAL

  • Heating of storage sheds, work areas, halls sorting areas, construction sites, greenhouses and polytunnels.
  • Drying of new construction and renovation projects.
  • Drying and preservation of agricultural products.

40019003__10__MANUAL__IMA__LR40022010__06 IMA 61 111 150 200 RAD40022020__03 IMA 61 111 150 AXIAAL

Frequently Asked Questions

The temperature of the intake air is cooled back by about 12°C. It is therefore important to always recirculate the air from the room to be cooled. (In this case, the air is drawn in from the room and blown back into the room with a temperature approximately 12°C lower).

This depends on the area and volume, insulation of the building and application. A rule of thumb is 40W per m3 for insulated buildings and 60W per m3 for tents, for example.

For all heaters with an oil-fired auxiliary burner, the burner can be replaced with a gas-fired auxiliary burner.

Read more

Neem contact op!

Send an Email +31 (0)7 65 87 34 50


Download onze catalogus

Download now
Productie in eigen fabriek
NL
Nederlandse kwaliteit sinds 1958
Wereldwijde levering
Klantspecifiek mogelijk
Offers
  • Sectors
Sectors
  • Construction
  • Agriculture
  • Emergency heating
  • Military
  • Industry
  • Pest control
Additionals
  • Client projects
  • Careers
  • About us
  • Frequently Asked Questions
Thermobile Industries B.V.

Konijnenberg 80

4825 BD Breda

Nederland

Route via Google Maps

+31 (0)7 65 87 34 50


Contact

Linkedin

  • Sectors

  • Construction
  • Agriculture
  • Emergency heating
  • Military
  • Industry
  • Pest control

  • Client projects
  • Careers
  • About us
  • Frequently Asked Questions

Konijnenberg 80

4825 BD Breda

Nederland

Route via Google Maps

+31 (0)7 65 87 34 50


Contact

Linkedin

  • Terms and Conditions
  • Privacybeleid
Part of
×
close close

Login

Forgot your password?

No account yet? Apply here